跳转到主内容

CFBMC-7024:主动学习周期期间 AFF C800 低电压关机

Views:
4
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
HW
Last Updated:

问题描述

AFF C800 在 BMC 版本 10.9P1 的主动学习周期中因电池问题而关闭,一旦接管,它就能够完成回馈并上线而不会出现问题。

您可能会看到以下消息:

Mon Jun 09 02:10:51 -0500 [<node>: env_mgr: nvmem.battery.voltageLowWarn:alert]: The NVMEM battery voltage is below normal (5600 mV).
Mon Jun 09 02:11:42 -0500 [<node>: env_mgr: nvmem.battery.voltageLow:EMERGENCY]: The NVMEM battery voltage is critically low (5500 mV). To prevent data loss, the system will shut down in 5 minutes.
Mon Jun 09 02:11:52 -0500 [<node>: env_mgr: callhome.battery.warning:alert]: Call home for BATTERY (voltage low) WARNING.
Mon Jun 09 02:12:42 -0500 [<node>: env_mgr: callhome.battery.failure:EMERGENCY]: Call home for BATTERY (voltage low) CRITICAL.
Mon Jun 09 02:16:42 -0500 [<node>: env_mgr: monitor.shutdown.emergency:EMERGENCY]: Emergency shutdown: Environmental Reason Shutdown (Battery voltage critical)
Mon Jun 09 05:10:52 -0500 [<node>: cf_main: cf.fsm.takeoverByPartnerEnabled:notice]: Failover monitor: takeover of <node> by <partner_node> enabled
Mon Jun 09 05:10:53 -0500 [<node>: statd: monitor.nvramLowBattery:EMERGENCY]: NVRAM battery is dangerously low.
Mon Jun 09 05:10:53 -0500 [<node>: statd: monitor.nvramLowBattery.notice:notice]: If the NVRAM battery is dangerously low, the system shuts down automatically every 24 hours to encourage you to replace it. If you reboot the system it will run for another 24 hours before shutting down.
Mon Jun 09 05:10:53 -0500 [<node>: statd: callhome.battery.low:alert]: Call home for BATTERY_LOW.



可能会看到以下自动支持警报:

HA Group Notification (BATTERY (voltage low)) ALERT
HA Group Notification (BATTERY (voltage low)) EMERGENCY



BMC 日志表明在电池电压关闭时间前不久开始的学习周期:

LrnCycleStartDate : 25-06-09-04:09
LrnCycleStartFCC : 0x0545
LrnCycleEndFCC : 0x0000
LrnCycleEndDate :
LrnCycleEntry : 0x05
LrnCycleAttempts : 0x03
LrnCycleResult : 0x00
LrnCycleStartVDSG : 0x0000
LrnCycleEndVDSG : 0x0000
LrnCycleStartTmp : 0x0000
LrnCycleEndTmp : 0x0000

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.