使用光缆时X1151A端口未联机
适用场景
- X1151A双100G以太网控制器声卡
- X65405 QSFPs收发器
- X66200-MPO <n>光缆
问题描述
- 使用光缆时、e3A/e3b端口需要15-20分钟才能联机:
Wed Dec 13 11:56:02 +0800 [Node-02: nblade1: netif.linkInfo:info]: Ethernet adapter e3a: Link Resetting.
Wed Dec 13 11:56:05 +0800 [Node-02: nblade1: netif.linkInfo:info]: Ethernet adapter e3b: Link Resetting.
Wed Dec 13 12:14:32 +0800 [Node-02: vifmgr: vifmgr.portup:notice]: A link up event was received on node Node-02, port e3b.
Wed Dec 13 12:14:32 +0800 [Node-02: vifmgr: vifmgr.portup:notice]: A link up event was received on node Node-02, port e3a.
- 在某些情况下、这可能表现为"轻拍"端口问题描述、而不是未启动的端口。
- 如果遇到此ONTAP、则自动问题描述升级可能会暂停、并显示以下错误:
[Node-01: upgrademgr: upgrademgr.update.pausedErr:error]: The automated update of the cluster has been paused due to the following reason: Error: {Update timeout occured in State[Giveback]-- Tasks Pending in nodes Task Name: do-giveback-job}, Action: {Ensure that nodes are healthy and try resuming the update operation after some time}
Wed Dec 13 12:10:51 +0800 [Node-01: notifyd: callhome.andu.pausederr:alert]: params: {'subject': 'AUTOMATED NDU PAUSED ON NODE: MUM', 'epoch': '6ddXXX0-bXX3-4XXf-b7c1-aXXXXXXXXXX67'}
- 手动将交换机端口速度设置为100G不会解决问题描述问题。
- 在交换机命令行界面中、端口可能会 由于
show interface brief
命令输出中的闪烁而报告errdisable
。 - 使用铜缆时、e3a/e3b端口会立即联机。