X1146A以太网卡致命错误导致节点重新启动
适用场景
- ONTAP 9
- X1116A/X1146A以太网卡
问题描述
- 节点意外重新启动、并报告控制台消息:
t6nex0: * PL_INT_CAUSE 0x1940c = 0x00000001, E 0x1fffe77d, F 0x00000000
t6nex0: * [0x00000001] CIM
t6nex0: ! CIM_HOST_INT_CAUSE 0x7b2c = 0x00000004, E 0x007dffe6, F 0x007dffe6
t6nex0: ! [0x00000004] CIM TIMER0 interrupt t6nex0: - CIM_HOST_UPACC_INT_CAUSE 0x7b34 = 0x00001100, E 0x7fffeeff, F 0x3fffeeff
t6nex0: - [0x00001000] CIM block read from flash space
t6nex0: - [0x00000100] CIM block read from boot space t6nex0: firmware reports adapter error: Crash (0xc014c010) t6nex0: encountered fatal error, adapter stopped (0).
- 之后、还会显示以下崩溃消息:
PANIC : page fault (supervisor write data, page not present) on VA 0x48 cs:rip 0x20:0xffffffff80a4eb89 rflags
0x10246
version: 9.11.1P8: Thu Apr 6 20:02:50 EDT 2023
- 在MetroCluster IP系统中、如果 X1166A以太网卡 发生故障、则会通过发生原因使 配对节点因检测信号丢失而被接管。