适用场景

  • MetroCluster IP后端兼容交换机。示例:
    • N9K-C93240YC-FX2
    • N9K-C9336C-FX2-E

问题描述

  • 报告的运行状况监控器警报:

[Node-1: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process cshm:SwitchCommunityString_Alert[cluster-stor-sw2(XXXXXXXXXX)].

[Node-1: cshmd: hm.alert.raised:alert]: Alert Id =UnsupportedSwitch_Alert, Alerting Resource = cluster-stor-sw2(XXXXXXXXXX) raised by monitor ethernet-switch

  • system health alert show 输出:

Node: Node-1
Monitor: ethernet-switch
Alert ID:SwitchCommunityString_Alert
Alerting Resource: cluster-stor-sw2(XXXXXXXXXX)
Subsystem: Switch-Health
Indication Time: Fri Nov 04 07:07:04 2022
Perceived Severity: Major
Probable Cause: Configuration_error
Description: Ethernet switch "cluster-stor-sw2(XXXXXXXXXX)" with IP address "10.X.XXX.XXX" is not reachable via SNMP. Incorrect SNMP community string might be configured on the Ethernet switch.
Corrective Actions: Check the SNMP community string on the Ethernet switch to verify that the expected community string is configured. Use the "system switch ethernet show -snmp-config" command to view the expected community string.
Possible Effect: Ethernet switch communication problems and accessibility issues.

Node: Node-1
Monitor: ethernet-switch
Alert ID:UnsupportedSwitch_Alert
Alerting Resource: cluster-stor-sw2(XXXXXXXXXX)
Subsystem: Switch-Health
Indication Time: Fri Nov 04 07:07:04 2022
Perceived Severity: Major
Probable Cause: Configuration_error
Description: Unsupported Ethernet switch is detected.
Corrective Actions: Unsupported Ethernet switch "cluster-stor-sw2(XXXXXXXXXX)" found. Connect a supported Ethernet switch to the network.
Possible Effect: Communication problems and network connectivity issues occur.

  • 由于以下警报、交换机运行状况将降级:

Cluster::> system health subsystem show
Subsystem         Health
----------------- ------------------
SAS-connect       ok
Environment       ok
Memory            ok
Service-Processor ok
Switch-Health     degraded
CIFS-NDO          ok
Motherboard       ok
IO                ok
MetroCluster      ok
MetroCluster_Node ok
FHM-Switch        ok
FHM-Bridge        ok
SAS-connect_Cluster ok

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.