适用场景
- MetroCluster FC
- ATTO光纤网桥7x00
问题描述
- ATTO光纤网桥7x00意外重新启动
dumpeventlog all
输出显示Abort Task Set
单个FC端口出现大量错误:
0A2EBC 07:46:00 03/13/22 INFO FC TM Cmd Rcvd: Abort Task Set to LUN:17 on FC Port 1
0A2EBE 07:48:35 03/13/22 INFO FC TM Cmd Rcvd: Abort Task Set to LUN:12 on FC Port 1
0A2EC0 07:50:10 03/13/22 INFO FC TM Cmd Rcvd: Abort Task Set to LUN:16 on FC Port 1