适用场景

  • MetroCluster
  • 从 MetroCluster FC 过渡到 MetroCluster IP
  • metrocluster configure 已成功

问题描述

  • storage failover show 显示接管错误:
 Takeover Node Partner Possible State Description -------------- -------------- -------- ------------------------------------- xxxxxxxxxx-n01 xxxxxxxxxx-n02 true Connected to xxxxxxxxxx-n02 xxxxxxxxxx-n02 xxxxxxxxxx-n01 true Connected to xxxxxxxxxx-n01 xxxxxxxxxx-n03 xxxxxxxxxx-n04 false Waiting for xxxxxxxxxx-n04, Takeover is not possible: Storage failover interconnect error, NVRAM log not synchronized, Disk inventory not exchanged xxxxxxxxxx-n04 xxxxxxxxxx-n03 false Waiting for xxxxxxxxxx-n03, Takeover is not possible: Storage failover interconnect error, NVRAM log not synchronized, Disk inventory not exchanged
  • 适配器通过显示脱机 metrocluster interconnet adapter show, ,但物理状态为已启动:

gtncl4005-n03 mgtncl4005-n04 HA enabled offline
                      e0b    iWARP  Up
                      e1b    iWARP  Up
        mgtncl3005-n03 DR enabled offline
                      e0b    iWARP  Up
                      e1b    iWARP  Up
        mgtncl3005-n04 AUX enabled offline
                      e0b    iWARP  Up
                      e1b    iWARP  Up

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.