跳转到主内容

执行聚合修复后报告SyncMirror丛失败

Views:
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
not set
Last Updated:

适用场景

  • ONTAP 9
  • MetroCluster FC
  • 采用NetApp E系列后端的FlexArray

问题描述

  • 在强制进行逐项切换后、将在接受站点上运行聚合修复、此时将显示成功:
 
mcc.drsom.fsmStateTrans:debug]: params: {'from_state': 'heal_aggrs_in_progress', 'event': 'success'}
mcc.drsom.fsmStateEntry:debug]: params: {'state': 'heal_aggrs_complete'}
 
  • 接下来会出现SyncMirror丛故障:
 
raid.assim.rg.missingChild:debug]: Aggregate stor168sp4, rgobj_verify: RAID object 0 has only 4 valid children, expected 5.
raid.assim.plex.missingChild:debug]: Aggregate stor168sp4, plexobj_verify: Plex 0 only has 0 working RAID groups (1 total) and is being taken offline
raid.assim.rg.missingChild:debug]: Aggregate stor168sp1, rgobj_verify: RAID object 0 has only 5 valid children, expected 6.
raid.assim.plex.missingChild:debug]: Aggregate stor168sp1, plexobj_verify: Plex 0 only has 0 working RAID groups (1 total) and is being taken offline
raid.assim.rg.missingChild:debug]: Aggregate stor168sp15, rgobj_verify: RAID object 0 has only 4 valid children, expected 5.
raid.assim.plex.missingChild:debug]: Aggregate stor168sp15, plexobj_verify: Plex 6 only has 0 working RAID groups (1 total) and is being taken offline
 
  • 切换后的聚合上的远程镜像丛缺少LUN:
 
Aggregate stor168sp4 (online, raid0, mirror degraded) (block checksums)
  Plex /stor168sp4/plex0 (offline, failed, inactive)
   RAID group /stor168sp4/plex0/rg0 (partial, block checksums)
 
    RAID Disk Device        HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
    --------- ------        ------------- ---- ---- ---- ----- --------------   --------------
    data FAILED        N/A             13972000/ -
    data   lns24bb1:14.126L28  0f   -  -      0  LUN  N/A 13972000/28614656000 14000000/28672000000 
    data   lns24ab1:14.126L29  0e   -  -      0  LUN  N/A 13972000/28614656000 14000000/28672000000 
    data   lns24ab1:14.126L31  0e   -  -      0  LUN  N/A 13972000/28614656000 14000000/28672000000 
    data   lns24bb1:14.126L30  0f   -  -      0  LUN  N/A 13972000/28614656000 14000000/28672000000 
    Raid group is missing 1 disk.
 
 
  • 在已断开的切换集群池中发现缺少LUN、并且LUN不正确地归已切换集群所有:
 
Aggregate stor168sp4 (failed, raid0, partial) (block checksums)
  Plex /stor168sp4/plex0 (offline, failed, inactive)
   RAID group /stor168sp4/plex0/rg0 (partial, block checksums)
 
    RAID Disk Device        HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)   Phys (MB/blks)
    --------- ------        ------------- ---- ---- ---- ----- --------------   --------------
    data   lns24ab1:14.126L27  0e   -  -      0  LUN  N/A 13972000/28614656000 14000000/28672000000 
    data FAILED        N/A             13972000/ -
    data FAILED        N/A             13972000/ -
    data FAILED        N/A             13972000/ -
    data FAILED        N/A             13972000/ -
    Raid group is missing 4 disks.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 