适用场景

  • MetroCluster
  • ONTAP 9
  • ATTO FibreBridge 7500N/7600N

问题描述

  • Active IQ Unified Manager 会生成警报:

Switch To FC-SAS Bridge FC Link Down

  • EMS日志包含错误:

Fibre Channel FibreBridge7600N Bridge ATTO_2000001086ac1234 S/N: FB7600N123456 WWN: 2000001086ac1234 FC Port FC_PORT2 offline

  • ATTO网桥日志显示FC端口反复出现启动和关闭的实例:

0C037D 08:37:39 01/20/23 INFO FC Async Event, Link Down, PTP/Fabric, 32Gb on FC Port 2
0C037E 08:37:39 01/20/23 INFO FC Port 2 Link Down detected.
0C037F 08:37:39 01/20/23 INFO FC Loop Is Not Operational on FC Port 2
0C0380 08:37:39 01/20/23 INFO FC Port ID 0x080200 [0x001] LogOut Pt:2100000109B631234
0C0381 08:37:39 01/20/23 INFO FC Port ID 0x080600 [0x002] LogOut Pt:2100000109B632345
0C0382 08:37:39 01/20/23 INFO FC Port ID 0x060200 [0x003] LogOut Pt:2100000109B633456
0C0383 08:37:39 01/20/23 INFO FC Port ID 0x060600 [0x004] LogOut Pt:2100000109B634567
0C0384 08:37:39 01/20/23 INFO Initiator 200000109B631234 logged out.
0C0385 08:37:39 01/20/23 INFO Initiator 200000109B632345 logged out.
0C0386 08:37:39 01/20/23 INFO Initiator 200000109B633456 logged out.
0C0387 08:37:39 01/20/23 INFO Initiator 200000109B634567 logged out.
0C0388 08:37:39 01/20/23 INFO FC Async Event, Link Up, PTP/Fabric, 32Gb on FC Port 2
0C0389 08:37:39 01/20/23 INFO FC Port 2 Link Up. Rate: 32Gb, Topology: ptp.
0C038A 08:37:39 01/20/23 INFO FC Loop Is Operational on FC Port 2
0C038B 08:37:40 01/20/23 INFO FC Fabric Login Complete on FC Port 2

  • 由于交换机端口上出现CRC错误、已更换网桥FC端口和交换机端口SFP、但问题描述 未得到解决。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.