跳转到主内容

SwitchIslIfDownWarn_Alert,用于MetroCluster交换机

Views:
4
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster<a>2009624073.</a>
Last Updated:

适用场景

  • ONTAP 9.13.1.
  • MetroCluster IP
  • Cisco以太网 交换机
  • 集群交换机运行状况监控(CSHM)

问题描述

  • CSHM 可以在事件日志中观察到警报
[Node-01 cshmd: hm.alert.raised:alert]: Alert Id = SwitchIslIfDownWarn_Alert , Alerting Resource = SW01(XXXXXXXXXXX)/Ethernet1/22/3 raised by monitor ethernet-switch
  • SYSTEM-HEALTH-ALERT.XML :

Node: SW01

Alert ID: SwitchIslIfDownWarn_Alert
Resource: port-channel11
Severity: Major
Indication Time: Mon Jun 26 11:54:04 2023
Suppress: false
Acknowledge: false

Probable Cause: The cable attached to the ISL port "SW01(XXXXXXXXXXX)/port-channel11" with the description of "" might be faulty.

For the port-channel, please check each individual link.

Possible Effect: Inter- or Intra-cluster redundancy might be lost.
Corrective Actions:
1) Check whether the cable is fully inserted into the interface port on both ends.
2) Reconnect the ISL port using another cable. After reconnecting it, verify whether the link of the ISL port is up by executing the commands per the switch configuration guide or by checking whether the Link status LED is on.

  • 交换机固件和RCF文件是最新的。
  • 的输出 show tech-Support 显示分支缆线位于交换机的一个端口通道上:
 * Ports 21-24: MetroCluster-IP ISL Ports, VLAN 10, Port Channel 11, breakout

------------------------------------------------------------------------------------------
Port-channel VLAN    Type Mode   Status  Reason                              Speed   Protocol
Interface
------------------------------------------------------------------------------------------
Po1          1       eth  trunk  up      none                                a-100G(D)  lacp
Po10         1       eth  trunk  up      none                                 a-40G(D)  lacp
Po11         1       eth  trunk  down   No operational members                auto(D)  lacp

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.