远程磁盘仅报告MetroCluster IP中的一个节点出现故障
- Views:
- 11
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2009-397734</a>
- Last Updated:
适用场景
- ONTAP 9
- MetroCluster IP
问题描述
- 一个节点报告一些远程磁盘出现故障。
cluster1::> system node run -node cluster1_node01 -command sysconfig -a
slot 0: Virtual iSCSI Host Adapter 0m
10.9 : NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D) (Failed)
10.12: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM) (Failed)
10.13: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ) (Failed)
slot 0: Virtual iSCSI Host Adapter 0v
10.9 : NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D) (Failed)
10.12: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM) (Failed)
10.13: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ) (Failed)
- 其配对节点和灾难恢复站点节点报告磁盘正常。
cluster1::> system node run -node cluster1_node02 -command sysconfig -a
slot 0: Virtual iSCSI Host Adapter 0m
10.9 : NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
10.12: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
10.13: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)
slot 0: Virtual iSCSI Host Adapter 0v
10.9 : NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
10.12: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
10.13: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)
cluster2::> system node run -node cluster2_node01 -command sysconfig -a
slot 0: SAS Host Adapter 0a (PMC-Sierra PM8072 rev. C, SAS, <UP>)
10.9 : NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
10.12: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
10.13: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)
slot 0: SAS Host Adapter 0d (PMC-Sierra PM8072 rev. C, SAS, <UP>)
10.9 : NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXX8D)
10.12: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXSM)
10.13: NETAPP X357_SLBPE3T8ATE NA50 3662.5GB 520B/sect (HSXXXXQJ)