升级交换机固件后,远程磁盘丢失
适用场景
- AFF-A220
- MetroCluster IP
- 后端交换机升级
- ONTAP <9.7P15
- ONTAP <9.8P6
- ONTAP <9.9.1P1
问题描述
在交换机固件升级聚合显示为已降级且远程丛上的磁盘报告为缺失 / 故障后
cluster::>aggr show-status
Aggregate aggr1 (online, raid_dp, mirror degraded, fast zeroed) (block checksums)
Plex /aggr1/plex0 (online, normal, active, pool0)
RAID group /aggr1/plex0/rg0 (normal, block checksums)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity 0b.50.0P2 0b 50 0 SA:B 0 SSD N/A 445732/912859136 445740/912875520 (fast zeroed)
..
data 0b.50.22P1 0b 50 22 SA:B 0 SSD N/A 445732/912859136 445740/912875520 (fast zeroed)
Plex /aggr1/plex1 (offline, failed, inactive, pool1)
RAID group /aggr1/plex1/rg0 (partial)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
dparity FAILED N/A 445732/ -
parity FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
data FAILED N/A 445732/ -
Raid group is missing 23 disks.