跳转到主内容

Plexes fail during Motherboard replacement

Views:
2
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

Applies to

  • MetroCluster IP
  • Motherboard replacement
  • SyncMirror Plex Failed
  • ONTAP 9

Issue

During a Motherboard replacement in a MetroCluster IP one or more remote plexes fail
  • AutoSupport  reports the events:

HA Group Notification from X_siteB_N1 (SYNCMIRROR PLEX FAILED) ALERT 
HA Group Notification from X_siteB_N1(Health Monitor process schm: DualControllerHa_Alert[xxxxxxxxxxxx) ALERT
HA Group Notification from X_siteB_N2(HA GROUP ERROR: DISK/SHELF COUNT MISMATCH) ERROR
HA Group Notification from X_siteB_N1(DISK REDUNDANCY FAILED) ERROR
HA Group Notification from X_siteB_N1(FILESYSTEM DISK NOT RESPONDING) ERROR

  • EMS reports the following messages 

Fri Aug 22 18:05:44 +0800 [X_siteB_N1: dmgr_thread: raid.notify.on.non.persistent.failure:debug]: Received SDM_NOTIFY_ON_NON_PERSISTENT_FAILURE for disk uid 6000C500:EC81BF43:500A0981:00000002:00000000:00000000:00000000:00000000:00000000:00000000, originating sysid 123456789.
Fri Aug 22 18:05:44 +0800 [X_siteB_N1: config_thread: raid.config.filesystem.disk.not.responding:notice]: File system Disk 0v.i2.1L26 Shelf 21 Bay 1 [NETAPP   X319_SLBPE7T6ATE NA51] S/N [HSR04KXK] UID [5000C500:EC81BF43:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] is not responding

  • SYSCONFIG-R section

Plex /X_siteB_N1_data_01/plex1 (offline, failed, inactive, pool1)
    RAID group /X_siteB_N1_data_01/plex1/rg0 (partial, block checksums)

      RAID Disk Device     HA  SHELF BAY CHAN Pool Type  RPM  Used (MB/blks)    Phys (MB/blks)
      --------- ------     ------------- ---- ---- ---- ----- --------------    --------------
      dparity FAILED      N/A                        3650699/ -
      parity FAILED      N/A                        3650699/ -
      data     0v.i1.3L28P1 0v    21  3          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0v.i1.3L47P1 0v    21  22         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (reconstruct stalled)
      data     0m.i1.1L30P1 0m    21  5          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0v.i1.2L32P1 0v    21  7          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0m.i1.0L33P1 0m    21  8          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0m.i1.0L34P1 0m    21  9          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data     0v.i1.3L36P1 0v    21  11         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data     0v.i1.2L40P1 0v    21  15         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data FAILED      N/A                        3650699/ -
      data     0v.i1.2L46P1 0v    21  21         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data FAILED      N/A                        3650699/ -
      data     0m.i1.1L27P1 0m    21  2          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0m.i1.1L31P1 0m    21  6          1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      data     0v.i1.3L38P1 0v    21  13         1   SSD   N/A 3650699/7476632576 3650707/7476648960 (fast zeroed)
      Raid group is missing 11 disks.

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.