更换ATTO SFP后Plex失败
适用场景
- 延伸型 MetroCluster
- ONTAP 9
- 具有故障SFP的ATTO 7500N
问题描述
- 延伸型MetroCluster 中的一个存储连接已脱机
示例:
slot 1: FC Host Adapter 1d (Emulex XE201 rev. 48, <OFFLINE (hard)>)
Board name: 111-02455
Serial Number: FC54482752
Firmware rev: 12.0.378.1
Host Port Id: N/A
FC Node Name: 2:000:000000:000000
FC Port Name: 1:000:000000:000000
Link Data Rate: N/A
- 在更换ATTO网桥上的故障SFP后、立即触发标题为的AutoSupport
SYNCMIRROR PLEX FAILED
- 许多磁盘在中显示为故障
sysconfig -r
Aggregate root (online, raid4, mirror degraded) (block checksums)
Plex /root/plex0 (offline, failed, inactive, pool0)
RAID group /root/plex0/rg0 (partial)
RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks)
--------- ------ ------------- ---- ---- ---- ----- -------------- --------------
parity FAILED N/A 1713523/ -
data FAILED N/A 1713523/ -
Raid group is missing 2 disks.
online
、只有丛保留 offline