更换主板后分区显示出现故障
适用场景
- ONTAP 9
- AF-A400
- MetroCluster IP
- ADP (高级磁盘分区)
问题描述
- 在为一个四节点MetroCluster IP的一个节点更换主板后、多个聚合的远程丛中的多个分区显示出现故障
示例:
Plex /aggr1/plex1 (offline, failed, inactive) RAID group /aggr1/plex1/rg0 (partial, block checksums) RAID Disk Device HA SHELF BAY CHAN Pool Type RPM Used (MB/blks) Phys (MB/blks) --------- ------ ------------- ---- ---- ---- ----- -------------- -------------- dparity FAILED N/A 1757716/ - parity FAILED N/A 1757716/ - data FAILED N/A 1757716/ - data FAILED N/A 1757716/ - data 0m.i0.1L31P1 0m 10 18 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0m.i0.1L34P1 0m 10 20 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0v.i0.1L36P1 0v 10 22 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0m.i0.1L37P1 0m 10 23 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data FAILED N/A 1757716/ - data FAILED N/A 1757716/ - data 0m.i0.1L33P1 0m 10 19 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0v.i0.3L35P1 0v 10 21 1 SSD N/A 1757716/3599803904 1757724/3599820288 (fast zeroed) data 0m.i0.0L18P1 0m 11 6 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0v.i0.3L12P1 0v 11 7 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0m.i0.1L26P1 0m 11 8 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0v.i0.1L25P1 0v 11 9 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0m.i0.1L29P1 0m 11 10 1 SSD N/A 1757716/3599803904 1757724/3599820288 data 0v.i0.3L31P1 0v 11 11 1 SSD N/A 1757716/3599803904 1757724/3599820288 Raid group is missing 6 disks.
- 无法取消分区故障、因为实际容器磁盘未出现故障