跳转到主内容

节点无响应且无法启动

Views:
22
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
hw
Last Updated:

适用场景

  • FAS8200
  • AFF-A300
  • AFF-A400
  • AFF-A250
  • FAS2750
  • FAS2620
  • 主板上没有处于活动状态的指示灯
  • 如果是MetroCluster、则在出现故障时触发了AUSO

问题描述

  • 发生接管或自动计划外切换(AUSO) 、并且此节点完全无响应。
  • 通过重新拔插主板硬重启电源后、节点无法恢复。
  • 节点无法通过system power onsystem power cycle 通过BMC或SP启动。
  • SP/BMC 报告Running Backup Firmware并且多个传感器无法读取。

CPU0 Temp Avg       failed       -- C     --      --      -11 C     -1 C
CPU0 Temp Margin      failed       -- C     --      --      -11 C     -1 C
CPU0 Error         not_available    --
CPU0 Therm Trip      not_available    --
CPU0 Hot          not_available    --
Memory0 Hot        not_available    --
PCH Hot          not_available    --
P5V            not_available    -- mV    4245 mV    4343 mV    5660 mV    5807 mV
P3.3V           not_available    -- mV    2960 mV    3040 mV    3568 mV    3664 mV
PVDDQ DDR4 AB       not_available    -- mV     9 mV     19 mV    2454 mV    2463 mV
PVTT DDR4 AB        not_available    -- mV     9 mV     19 mV    2454 mV    2463 mV
PVCCP CPU0         not_available    -- mV     9 mV     19 mV    2454 mV    2463 mV
P12V            not_available    -- mV     0 mV     --      --     15810 mV
P12V Curr         not_available    -- mA     0 mA     --      --     21420 mA

  • 管理控制台和服务处理器可能无法访问。

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.