节点报告已关闭或未使用的 FC 端口的 StorageFCAdapterFault_Alert
适用场景
- ONTAP 9
- MetroCluster
- FAS / AFF
- 启动程序模式下的FC端口
问题描述
- 节点会在每次重新启动后针对已关闭的 FC 端口发送针对 StorageFCAdapterFault 的 AutoSupport 警报。
Health Monitor process nchm: StorageFCAdapterFault_Alert[500##########]) ALERT
- 报告的端口未在使用中。
- MetroCluster_Node子系统运行状况降级:
cluster::> system health subsystem show
Subsystem Health
----------------- ------------------
SAS-connect ok
Environment ok
Memory ok
Service-Processor ok
Switch-Health ok
CIFS-NDO ok
Motherboard ok
IO ok
MetroCluster ok
MetroCluster_Node degraded
FHM-Switch ok
FHM-Bridge ok
SAS-connect_Cluster
ok
13 entries were displayed.
- 从clustershell可以看到运行状况警报、如下所示:
cluster::> system health alert show
Node: node-01
Resource: 4d
Severity: Major
Indication Time: Sat Aug 15 13:05:58 2020
Suppress: false
Acknowledge: false
Probable Cause: FC initiator adapter 4d is at fault.
Possible Effect: Resiliency of backend storage is compromised.
Corrective Actions: 1. Ensure that the FC initiator link has not been tampered with.
2. Verify the operational status of the FC initiator
adapter by using the command "system node run -node
local -command storage show adapter".