跳转到主内容

未复制MetroCluster SVM更改

Views:
3
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • MetroCluster
  • ONTAP 9
  • MetroCluster SVM更改不会在集群之间复制

问题描述

在此示例中、cluster02上的SVM已被删除、但此更改不会复制到cluster01、DR SVM也不会被删除。在metrocluster vserver showcluster01上的输出中仍显示此SVM、并且配置状态不正常。

cluster01
Cluster Name        Vserver         Partner                   Configuration State      
cluster01            Vserver001         Vserver001-mc              healthy         
cluster01          cluster01        cluster02                 healthy         
cluster02          cluster02        cluster01                 healthy
cluster02          Vserver002         Vserver002-mc              unhealthy

cluster02
Cluster Name       Vserver         Partner                   Configuration State
cluster01         Vserver001         Vserver001-mc              healthy
cluster01         cluster01        cluster02                 healthy
cluster02         cluster02        cluster01                 healthy

MGWD日志中将显示以下错误

server=mgwd: RPC: Timed out; netid=tcp fd=695 TO=60.0s TT=60.000s O=23576b I=0b CN=31985/17 VSID=-1 192.168.12.13:11104RPC: Timed out; netid=tcp fd=675 TO=60.0s TT=60.000s O=2912b I=0b CN=25923/3 VSID=-1 192.168.12.10:11104
server=mgwd: RPC: Timed out; netid=tcp fd=695 TO=60.0s TT=60.000s O=23576b I=0b CN=31985/17 VSID=-1 192.168.12.13:11104RPC: Timed out; netid=tcp fd=695 TO=60.0s TT=60.000s O=23576b I=0b CN=31985/17 VSID=-1 192.168.12.20:11104

在此示例中、192.168.12.X IP地址是集群间LIF、而配置复制服务(CRS)使用端口11104

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.