MetroCluster 切回失败SVM降级配置复制失败
适用场景
- MetroCluster IP
- ONTAP 9
- MetroCluster 正在切换
问题描述
metrocluster switchback
出现故障metrocluster operation history
显示 ""。
Failed to validate the node and cluster components before the switchback operation.
CL02 (non-overridable veto): The Vserver configuration state was set to "degraded" because configuration replication failed. Reason: MetroCluster Vserver stream operation failed. Run the "metrocluster vserver show -configuration-state degraded -fields corrective-action" command to view detailed recovery information. The configuration replication operation will be retried and the Vserver configuration state might change.
metrocluster vserver show
输出将失败原因显示为:
Unrecoverable error during configuration replication, requires manual intervention. Error: Cannot find ports in IPspace "Default" on Node "CL01-N01" for placing LIF "CL01-N01_LIF01" in Vserver "SVM01_CL01".
network port show
输出显示LIF的"IP空间默认值"中存在可用端口