MetroCluster切换/切换回失败 vserver 降级配置复制失败
适用场景
- MetroCluster IP
- ONTAP 9
问题描述
- MetroCluster切换或切回操作失败,并且
metrocluster operation history
显示:
Failed to validate the node and cluster components before the switchback operation.
CL02 (non-overridable veto): The Vserver configuration state was set to "degraded" because configuration replication failed. Reason: MetroCluster Vserver stream operation failed. Run the "metrocluster vserver show -configuration-state degraded -fields corrective-action" command to view detailed recovery information. The configuration replication operation will be retried and the Vserver configuration state might change.
- 这
metrocluster vserver show
输出显示失败的原因如下:
Unrecoverable error during configuration replication, requires manual intervention. Error: Cannot find ports in IPspace "Default" on Node "CL01-N01" for placing LIF "CL01-N01_LIF01" in Vserver "SVM01_CL01".
- 这
network port show
输出显示 IP 空间默认中存在可用于 LIF 的端口。 - 事件日志可能会报告以下内容:
[CL01-N01: mgwd: misconfig.lif.info.lost:notice]: LIF "CL01-N01_LIF01" in Vserver "SVM01_CL01-mc" incorrectly placed needs manual recovery. Reason: "MetroCluster DR node "CL01-N01" is offline. The LIF "CL01-N01_LIF01" belonging to Vserver "SVM01_CL01-mc" will be placed on the HA partner node "CL01-N02".".