跳转到主内容

MetroCluster网络LIF未使用配对集群上的预期接口

Views:
24
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • MetroCluster

问题描述

每个集群上的network interface show 输出报告MetroCluster DR Vserver上LIF的主端口与此Vserver的源集群上使用的接口不同。

例如:

clusterA::> network interface show
  (network interface show)
            Logical    Status     Network            Current       Current Is
Vserver     Interface  Admin/Oper Address/Mask       Node          Port    Home
----------- ---------- ---------- ------------------ ------------- ------- ----
vserver
            lif1         up/up    10.10.100.10/24    clusterA-01   e0c     true
            lif2         up/up    10.10.100.11/24    clusterA-02   e0d     true
            lif4         up/up    10.10.100.12/24    clusterA-02   vlan-11 true

                 
clusterB::> network interface show
  (network interface show)
            Logical    Status     Network            Current       Current Is
Vserver     Interface  Admin/Oper Address/Mask       Node          Port    Home
----------- ---------- ---------- ------------------ ------------- ------- ----                                        
vserver-mc
            lif1         up/down  10.10.100.10/24    clusterB-02  e0e     true
            lif2         up/down  10.10.100.11/24    clusterB-01  e0c     true
            lif4         up/down  10.10.100.12/24    clusterB-01  vlan-22 true

 

 

执行

执行

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.