问题

切换后、灾难恢复( DR )站点 FC LIF 处于脱机状态。 

在切换期间、 DR 站点上的 FC LIF 会登录到交换机。

交换机拒绝了这种情况、因为它认为灾难站点上的 LIF 仍在运行。

 

节点

FCP target 0g reported a port configuration change. FDISC RJT - FDISC failed because a LS_RJT was received for virtual port

 

交换机日志

NPIV port 7/18 has same Port WWN as old port 7/38 with pid 0x32d641 as part of duplicate Port WWN detection policy.

 

 