在光纤通道适配器上检测到链路中断
适用场景
- MetroCluster
- ONTAP 9
- SAN
问题描述
光纤通道主机适配器脱机或发生闪烁。
EMS日志:
[NODE_NAME: slifc_intrd: fci.link.break:error]: Link break detected on Fibre Channel adapter 2c. [NODE_NAME: slifc_timeout_3: fci.link.error:error]: Could not recover link on Fibre Channel adapter 2c after 30 seconds. Taking the adapter offline. [NODE_NAME: nchmd: hm.alert.raised:alert]: Alert Id = StorageFCAdapterFault_Alert , Alerting Resource = 100000109b4e2af2 raised by monitor node-connect [NODE_NAME: slifc_asyncd_3: fci.adapter.online:info]: Fibre Channel adapter 2c is now online. or [NODE_NAME: slifc_asyncd_3: fci.adapter.online:info]: Fibre Channel adapter 2c is now online.
命令行界面:
::>event log show -message-name *linkBreak*
Time Node Severity Event
------------------- ---------------- ------------- ---------------------------
5/22/2024 14:32:34 Node1 ERROR scsitarget.ispfct.linkBreak: Link break detected on Fibre Channel target adapter 0e. Firmware status code status1 0x2, status2 0x7, and status4 0x0.
5/22/2024 14:32:34 Node1 ERROR scsitarget.ispfct.linkBreak: Link break detected on Fibre Channel target adapter 0e. Firmware status code status1 0x2, status2 0x7, and status4 0x0.
2 entries were displayed.