InterconnectAdapterOfflineAlert 双节点扩展 MetroCluster 中的 FCVI 端口 2x
适用于
- 2 个节点
- 延伸型 MetroCluster
- ONTAP 9
- FC-VI 错误
问题描述
InterconnectAdapterOfflineAlert在没有交换机的双节点桥接延伸 MetroCluster 中在 FCVI 端口 2a 上报告。- 一个节点死机并显示消息:
PANIC: nested machine check exception detected on CPU 12, no coredump will be generated.
- 系统健康警报显示:
::> system health alert showNode: node-01Alert ID: InterconnectAdapterOfflineAlertResource: fcvi_device_0Severity: MajorIndication Time: Tue Mar 18 09:18:56 2025Suppress: falseAcknowledge: falseProbable Cause: Physical link on port 2a is offline.Possible Effect: DR protection of NVRAM mirror might be compromised. Corrective Actions: 1. Ensure that the FC-VI link has not been tampered with.2. Verify that the physical status of the FC-VI adapter is "Up" by using the command "metrocluster interconnect adapter show".3. If the configuration includes fabric switches, ensure that they are properly cabled and configured.- 事件日志显示以下消息:
Cluster-1:
Tue Aug 20 12:55:29 +0000 [node-01A: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 2a.Cluster-2:
Tue Aug 20 12:55:30 +0000 [node-02A: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 2a.