由于集群间端口关闭问题描述、导致集群间Bro并 网连接警报
适用场景
- AF/FAS/ASA
- ONTAP 9
- MetroCluster
问题描述
- 在检查日志时、我们在EMS日志中发现以下事件:
[?] Fri Jun 21 04:20:34 +0530 [Node-02: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0f: Link down, check cable.
[?] Fri Jun 21 04:20:35 +0530 [Node-02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node BFLNTAPCLA-02, port e0f.
[?] Fri Jun 21 04:20:48 +0530 [Node-02: vifmgr: vifmgr.reach.noreach:notice]: Network port e0f on node Node-02 cannot reach its expected broadcast domain Default:Replication. No other broadcast domains appear to be reachable from this port.
[?] Fri Jun 21 04:20:48 +0530 [Node-02: vifmgr: vifmgr.reach.skipped:notice]: Network port e0f on node Node-02 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
[?] Fri Jun 21 04:31:33 +0530 [Node-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: InterclusterBrokenConnectionAlert[Node-01].
- 从交换机日志中、我们发现未检测到Rx电源:
# show interface ethernet 1/10 transceiver details
Ethernet1/10
SFP Detail Diagnostics Information (internal calibration)
----------------------------------------------------------------------------
Current Alarms Warnings
Measurement High Low High Low
----------------------------------------------------------------------------
Temperature 43.48 C 75.00 C -5.00 C 70.00 C 0.00 C
Voltage 3.33 V 3.63 V 2.97 V 3.46 V 3.13 V
Current 6.99 mA 12.00 mA 1.00 mA 11.50 mA 2.00 mA
Tx Power -4.01 dBm 5.39 dBm -10.00 dBm 2.39 dBm -6.00 dBm
Rx Power N/A 5.39 dBm -12.75 dBm 2.39 dBm -8.72 dBm