跳转到主内容

由于集群间端口关闭问题描述、导致集群间Bro并 网连接警报

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster
Last Updated:

适用场景

  • AF/FAS/ASA
  • ONTAP 9
  • MetroCluster

问题描述

  • 在检查日志时、我们在EMS日志中发现以下事件:
[?]  Fri Jun 21 04:20:34 +0530 [Node-02: mgmt_port_link_status_poll: netif.linkDown:info]: Ethernet e0f: Link down, check cable.
[?]  Fri Jun 21 04:20:35 +0530 [Node-02: vifmgr: vifmgr.portdown:notice]: A link down event was received on node BFLNTAPCLA-02, port e0f.
 
[?]  Fri Jun 21 04:20:48 +0530 [Node-02: vifmgr: vifmgr.reach.noreach:notice]: Network port e0f on node Node-02 cannot reach its expected broadcast domain Default:Replication. No other broadcast domains appear to be reachable from this port.
 [?]  Fri Jun 21 04:20:48 +0530 [Node-02: vifmgr: vifmgr.reach.skipped:notice]: Network port e0f on node Node-02 was not scanned for reachability because it was administratively or operationally down at the time of the scan.
 [?]  Fri Jun 21 04:31:33 +0530 [Node-02: mgwd: callhome.hm.alert.major:alert]: Call home for Health Monitor process schm: InterclusterBrokenConnectionAlert[Node-01].
 
  • 从交换机日志中、我们发现未检测到Rx电源:
# show interface ethernet 1/10 transceiver details
 
Ethernet1/10
 
SFP Detail Diagnostics Information (internal calibration)
  ----------------------------------------------------------------------------
         Current        Alarms          Warnings
         Measurement   High     Low     High      Low
  ----------------------------------------------------------------------------
  Temperature  43.48 C     75.00 C   -5.00 C   70.00 C     0.00 C
  Voltage     3.33 V     3.63 V    2.97 V    3.46 V     3.13 V
  Current     6.99 mA    12.00 mA   1.00 mA   11.50 mA    2.00 mA
  Tx Power    -4.01 dBm    5.39 dBm  -10.00 dBm   2.39 dBm   -6.00 dBm
  Rx Power     N/A     5.39 dBm  -12.75 dBm   2.39 dBm   -8.72 dBm

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.