跳转到主内容

ISL端口因存在网络分路器而关闭

Views:
1
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
brocade<a>2010025237</a>
Last Updated:

适用场景

  • ISL Brocade交换机
  • ONTAP 9

问题描述

  • ISL端口已关闭
  • 从交换机日志中:

BrcsG610-switch1:admin> switchshow
switchName: BrcdG610-switch1
switchType: 170.0
switchState: Online
switchMode: Native
switchRole: Principal
switchDomain: 7
switchId: fffc07
switchWwn: 10:00:xx:xx:xx:xx:xx:dd
zoning: ON
switchBeacon: OFF
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================

22 22 071600 id 16G Online FC LE E-Port 10:00:xx:xx:xx:xx:xx:04 "BrcdG610-switch2" (downstream)(Trunk master)
23 23 071700 id 16G No_Sync FC LE


BrcdG610-switch1:admin> islshow
1: 22-> 22 10:00:xx:xx:xx:xx:xx:04 5 BrcdG610-switch2 sp: 16.000G bw: 16.000G TRUNK QOS CR_RECOV FEC


 

BrcdG610-switch1:admin> trunkshow
1: 22-> 22 10:00:xx:xx:xx:xx:xx:04 5 deskew 0 E-Port MASTER

 

BrcdG610-switch2:admin> switchshow
switchName: BrcdG610-switch2
switchType: 170.0
switchState: Online
switchMode: Native
switchRole: Subordinate
switchDomain: 5
switchId: fffc05
switchWwn: 10:00:xx:xx:xx:xx:xx:04
zoning: ON
switchBeacon: OFF
HIF Mode: OFF
Index Port Address Media Speed State Proto
==================================================

22 22 051600 id 16G Online FC LE E-Port 10:00:xx:xx:xx:xx:xx:dd "BrcdG610-switch1" (upstream)(Trunk master)
23 23 051700 id 16G In_Sync FC LE


BrcdG610-switch2:admin> islshow
1: 22-> 22 10:00:xx:xx:xx:xx:xx:dd 7 BrcdG610-switch1 sp: 16.000G bw: 16.000G TRUNK QOS CR_RECOV FEC


 

BrcdG610-switch2:admin> trunkshow
1: 22-> 22 10:00:xx:xx:xx:xx:xx:dd 7 deskew 0 E-Port MASTER



 

BrcdG610-switch1:admin> trunkdebug 22, 23
port 23 is not E/EX/F port

 

  • sfpshow 在两个交换机中、Rx和TX值均处于可接受范围内

  • 已使用电缆

  • 已验证SFP 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.