适用场景

  • MetroCluster IP
  • T6A 卡X1166A

问题描述

  • 事件日志中报告的接口转接:

    Thu Feb 22 08:00:16 +0200 [node-02: intr: netif.linkDown:info]: Ethernet e1b: Link down, check cable.
    Thu Feb 22 08:00:18 +0200 [node-02: intr: netif.linkUp:info]: Ethernet e1b: Link up.

  • 报告前端延迟较高
  • 命令已被操作并报告远程磁盘出现高延迟:

    Fri Feb 22 10:05:16 +0200 [node-02: disk_latency_monitor: shm.threshold.ioLatency:debug]: Disk 0m.i2.1L38 has exceeded the expected IO latency in the current window with average latency of 60 msecs and average utilization of 36 percent. Highest average IO latency: 0m.i2.1L19: 237 msecs
    2/22/2024 15:07:30 node-02 ERROR scsi.cmd.abortedByHost: Disk device 0m.i2.0L145: Command aborted by host adapter: HA status 0x13: cdb 0x28:ec234d10:0008.

  • 问题描述刚刚报告了本地、DR和AUX节点、配对节点上未报告任何问题
  • 如果要更改端口、则会临时修复问题描述
  • 更换 SFP和缆线 不会修复问题描述

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.