跳转到主内容

MetroCluster IP 安装期间 HA 互连中断

Views:
109
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>MetroCluster IP</a><a>1089161</a>
Last Updated:

状态信息

适用场景

  • MetroCluster IP
  • ONTAP 9.5及更高版本
  • MetroCluster安装
  • 基于MetroCluster IP的HA连接(IC RDMA)

问题描述

  • 配置MetroCluster IP时、HA互连在启动节点并配置集群后不会联机。

ClusterA::> cluster ha show
High Availability Configured: false

Warning: Cluster HA has not been configured.  Cluster HA must be configured
         on a two-node cluster to ensure data access availability in the
         event of storage failover. Use the "cluster ha modify -configured
         true" command to configure cluster HA.


ClusterA::> storage failover show
                              Takeover
Node           Partner        Possible State Description
-------------- -------------- -------- -------------------------------------
ClusterA-01   -             false   Waiting for partner, Takeover is not
                                       possible: Storage failover is
                                       disabled

ClusterA-02   -             false    Waiting for partner, Takeover is not
                                       possible: Storage failover is
                                       disabled

2 entries were displayed.

  • 在启动期间、可能会显示以下消息:

mccip_install_dr_ips: bootarg.ic_local_ip not set, bailing
iw_cxgbe: Chelsio T4/T5/T6 RDMA driver loaded

[cluster_A-01:cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of ClusterA-02 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).

  • 接口将报告为已关闭:

ClusterA::> run local sysconfig -v 5
        slot 5: Dual 40/100G Ethernet T62100-CR
                e5a MAC Address:    00:07:43:3e:cf:50 (auto-unknown-fd-down)
                e5b MAC Address:    00:07:43:3e:cf:58 (auto-unknown-fd-down)
                Device Type:        T6 2
                Firmware Version:   1.23.0.0
                Part Number:        110122860A0
                Hardware Revision:  0
                Serial Number:      PT28170188

  • 无法激活高可用性互连:
 ClusterA::> cluster ha modify -configured true Warning: High Availability (HA) configuration for cluster services requires that both SFO storage failover and SFO auto-giveback be enabled. These actions will be performed if necessary. Do you want to continue? {y|n}: y Error: command failed: Could not retrieve partner SFO information: entry doesn't exist.

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.