安装MetroCluster IP期间HA互连关闭
适用场景
- MetroCluster IP
- ONTAP 9.5及更高版本
- MetroCluster安装
- 基于MetroCluster IP的HA连接(IC RDMA)
问题描述
- 配置MetroCluster IP时、HA互连在启动节点并配置集群后不会联机。
ClusterA::> cluster ha show
High Availability Configured: false
Warning: Cluster HA has not been configured. Cluster HA must be configured
on a two-node cluster to ensure data access availability in the
event of storage failover. Use the "cluster ha modify -configured
true" command to configure cluster HA.
ClusterA::> storage failover show
Takeover
Node Partner Possible State Description
-------------- -------------- -------- -------------------------------------
ClusterA-01 - false Waiting for partner, Takeover is not
possible: Storage failover is
disabled
ClusterA-02 - false Waiting for partner, Takeover is not
possible: Storage failover is
disabled
2 entries were displayed.
- 在启动期间、可能会显示以下消息:
mccip_install_dr_ips: bootarg.ic_local_ip not set, bailing
iw_cxgbe: Chelsio T4/T5/T6 RDMA driver loaded
[cluster_A-01:cf.fsm.takeoverOfPartnerDisabled:error]: Failover monitor: takeover of ClusterA-02 disabled (HA interconnect error. Verify that the partner node is running and that the HA interconnect cabling is correct, if applicable. For further assistance, contact technical support).
- 接口将报告为已关闭:
ClusterA::> run local sysconfig -v 5
slot 5: Dual 40/100G Ethernet T62100-CR
e5a MAC Address: 00:07:43:3e:cf:50 (auto-unknown-fd-down)
e5b MAC Address: 00:07:43:3e:cf:58 (auto-unknown-fd-down)
Device Type: T6 2
Firmware Version: 1.23.0.0
Part Number: 110122860A0
Hardware Revision: 0
Serial Number: PT28170188
- 无法激活高可用性互连:
ClusterA::> cluster ha modify -configured true Warning: High Availability (HA) configuration for cluster services requires that both SFO storage failover and SFO auto-giveback be enabled. These actions will be performed if necessary. Do you want to continue? {y|n}: y Error: command failed: Could not retrieve partner SFO information: entry doesn't exist.
- 连接的交换机端口已关闭并显示状态
Link not connected