跳转到主内容

ATto网桥意外重新启动后、光纤通道适配器出现故障

Views:
39
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2008429971.</a>
Last Updated:

适用场景

  • ONTAP 9
  • 延伸型 MetroCluster
  • ATto 7500N/7600N光纤桥接

问题描述

在意外重新启动ATto网桥后、控制器报告"Link BreAK detected on Fibre Channel adapter (在光纤通道适配器上检测到链路中断)"。
 
 
::>event log show
 
事件日志报告链路关闭和网桥被删除:
 
[fci.link.break:error]: Link break detected on Fibre Channel adapter xx.
[isp2400_timeout_7: fci.link.error:error]: Could not recover link on Fibre Channel adapter after 30 seconds. Offlining the adapter
[dsbridge_admin: bridge.removed:info]: FC-to-SAS bridge X.125L0 [ATTO FibreBridge7600N 4.35] S/N [FB7600N000000] was removed.
 
 
此时将重新发现此网桥并报告重新启动:
 
[dsbridge_admin: bridge.discovered:info]: FC-to-SAS bridge X.125L0 [ATTO FibreBridge7600N 4.35] S/N [FB7600N000000] was discovered.
[dsbridge_admin: bridge.rebooted:debug]: FC-to-SAS bridge  X.125L0 [ATTO FibreBridge7600N 4.35] S/N [FB7600N000000] was rebooted.
[dsbridge_admin: callhome.bridge.reboot.unexp:alert]: Call home for Bridge Unexpected Reboot: FB7600N000000
 
 
适配器报告链路已恢复:
 
[slifc_asyncd_1: fci.adapter.link.online:info]: Fibre Channel adapter xx link online.
 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.