ATto网桥意外重新启动后、光纤通道适配器出现故障
- Views:
- 39
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2008429971.</a>
- Last Updated:
适用场景
- ONTAP 9
- 延伸型 MetroCluster
- ATto 7500N/7600N光纤桥接
问题描述
在意外重新启动ATto网桥后、控制器报告"Link BreAK detected on Fibre Channel adapter (在光纤通道适配器上检测到链路中断)"。
::>event log show
事件日志报告链路关闭和网桥被删除:
[fci.link.break:error]: Link break detected on Fibre Channel adapter xx.
[isp2400_timeout_7: fci.link.error:error]: Could not recover link on Fibre Channel adapter after 30 seconds. Offlining the adapter
[dsbridge_admin: bridge.removed:info]: FC-to-SAS bridge X.125L0 [ATTO FibreBridge7600N 4.35] S/N [FB7600N000000] was removed.
此时将重新发现此网桥并报告重新启动:
[dsbridge_admin: bridge.discovered:info]: FC-to-SAS bridge X.125L0 [ATTO FibreBridge7600N 4.35] S/N [FB7600N000000] was discovered.
[dsbridge_admin: bridge.rebooted:debug]: FC-to-SAS bridge X.125L0 [ATTO FibreBridge7600N 4.35] S/N [FB7600N000000] was rebooted.
[dsbridge_admin: callhome.bridge.reboot.unexp:alert]: Call home for Bridge Unexpected Reboot: FB7600N000000
适配器报告链路已恢复:
[slifc_asyncd_1: fci.adapter.link.online:info]: Fibre Channel adapter xx link online.