适用场景
- ONTAP 9
- MetroCluster IP
- MetroCluster IP后端交换机
问题描述
- 更新交换机RC框架 后、ISL端口关闭
- 报告一个或多个plexes的ONTAP运行状况监控失败:
cluster:> system health alert show
Node: cluster-01
Resource: aggr1
Severity: Major
Indication Time: XXX XXX XX XX:XX:XX XXXX
Suppress: false
Acknowledge: false
Probable Cause: Mirrored aggregate aggr1 has a failed plex.
Possible Effect: DR protection of backend storage is compromised.
Corrective Actions: If a plex failed:
1) Ensure that the ISLs are healthy if the configuration includes fabric switches.
2) Locate the problematic shelf and address any issues if seen.
3) Check if any disks are broken by using the command
"storage disk show -container-type broken".