跳转到主内容

Fabric MetroCluster — scsi.cmd.abortedByHost :错误

Views:
20
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

光纤 MetroCluster

问题描述

事件日志中会显示以下错误消息:
 
Cluster1::> event log show -message-name scsi.cmd.abortedByHost
Time         Node    Severity    Event
------------------- ------- ------------- ---------------------------
10/4/2020 07:09:46  Node01   ERROR      Disk device brocade-fab1-sw1:13.126L1506: Command aborted by host adapter: ...
10/4/2020 05:16:42  Node01   ERROR      Disk device brocade-fab1-sw3:13.126L542: Command aborted by host adapter: ...
10/4/2020 03:18:07  Node01   ERROR      Disk device brocade-fab1-sw3:13.126L1: Command aborted by host adapter: ...
 
 
上述SCSI错误通常表示 链路/物理层问题。一旦出现链路层问题、也会 scsi.path.excessiveErrors:error 报告:
 
Cluster1::> event log show -message-name scsi.path.excessiveErrors
Time         Node   Severity  Event
------------------- ------ -------- ---------------------------
10/4/2020 05:42:46  Node01  ERROR   Excessive errors encountered by adapter 11a on disk device brocade-fab1-sw1:13.126.
10/4/2020 05:16:42  Node01  ERROR   Excessive errors encountered by adapter 11a on disk device brocade-fab1-sw3:13.126.

 
 
  • scsi.cmd.abortedByHost 报告本地和远程交换机上的所有磁盘
  • scsi.path.excessiveErrors 由单个节点上的单个端口报告

因此、需要重点关注端口与其所连接的交换机之间的链路。statsclear 启动后、在启动程序所连接的端口上报告新的CRC错误:

brocade-fab1-sw1:admin> porterrshow 

     frames   enc  crc crc   too   too   bad   enc   disc   link  
   tx    rx   in   err g_eof  shrt   long   eof    out   c3   fail   

29:  8.4g 2.4g   0  128k 118k   184L   0     10k      0  565k   113L 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.