跳转到主内容

Fabric MetroCluster — ISL 端口上的链路重置

Views:
77
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • 光纤连接 MetroCluster
  • ONTAP 9
  • 后端Brocade交换机

问题描述

可能的症状:

  • 访问远程站点上的磁盘时、EMS日志中同时存在FC-VI适配器断开连接错误或传输错误:

[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = RAID, QP index = 3, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = MISC, QP index = 4, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = STREAM, QP index = 5, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = DRSOM_HB, QP index = 6, Remote node's system id = 123456789. 
[node1: ispfcvi2500_main1: fcvi.qlgc.ioErr:error]: FC-VI adapter: FCVI driver on port 1a received IO error. Status = FW detected response error(status code = 0x121), FCVI opcode = Write Request(0x1), QP name = RAID, QP index = 11, Remote node's system id = 123456789.
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = STREAM, QP index = 13, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = DRSOM_HB, QP index = 14, Remote node's system id = 123456789. 
[node1: fcvi_cm: fcvi.qlgc.sent.disconnect:notice]: FC-VI adapter: Disconnect request sent on port 1a. QP name = DRC_KILL, QP index = 15, Remote node's system id = 123456789. 

[node1: isp2400_timeout_2: fci.device.quiesce:debug]: Adapter 5a encountered a command timeout on Disk device REMOTE_FAB1_SW1:6.126 (0x06070600) LUN 22 cdb 0x2a:5a93b808:01f8 retry: 0 Quiescing the device.
[node1: isp2400_timeout_2: fci.device.timeout:debug]: HBA 5a encountered a device timeout on Disk device REMOTE_FAB1_SW1:6.126 (0x06070600) LUN 30 cdb 0x2a:5a93b818:01e8 retry: 0

  • Brocade交换机报告一个或多个ISL 接口已重置:

CHASSIS, WARNING, Brocade6505, Single RDY/Frame Loss detected and recovered on Slot 0,Port 8(12) rdy(0x1)/frame(0x0).
CHASSIS, WARNING, Brocade6505, Multi RDY/Frame Loss detected on Slot 0, Port 8
CHASSIS, WARNING, Brocade6505, Link Reset on Port S0,P10
2334, FID 128, INFO,switch1, Port (ID: 8) QoS is disabled.

  • 此节点可能会报告 另一站点上的故障磁盘:

[node1: disk_server_0: scsi.debug:debug]: shm_setup_for_failure disk REMOTE_FAB1_SW1:9.126L1024 (S/N XXXXXXXXXXXXXX) error 4000h

[node1: config_thread: raid.config.filesystem.disk.failed:error]: File system Disk n1_aggr/plex6/rg0/REMOTE_FAB1_SW1:9.126L1024 Shelf 12 Bay 23 [NETAPP X371_S1643960ATE NA54] S/N [XXXXXXXXXXXXXX] UID [5002538B:01290E60:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000] failed.

  • LUN可能会发生连接/断开、因此LUN可能 无法访问。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.