FC-VI适配器:由于接收帧错误、丢弃了接收到的帧
适用场景
- 光纤连接 MetroCluster
- ONTAP 9
问题描述
- EMS报告
Discarded a received frame because of a receive frame error
。
[Node-A: ispfcvi2500_main4: fcvi.qlgc.FrameDiscardErr:error]: FC-VI adapter: Discarded a received frame because of a receive frame error. Port 0f, QP name = WAFL, QP index = 4, exchange ID 0x1a5, address offset 0xa000, remote node's system id = xxxxxxx.
- 由于接收帧错误、可能会重置FFC-VI端口:
[Node-A: ispfcvi2500_main2: fcvi.qlgc.receive.error:error]: FC-VI adapter: Received bad frame on port 0f. Mailbox-1 = 520, Mailbox-2 = 324. Resetting the port.
[Node-A: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 0f.
[Node-A: fcvi_reset_proc: callhome.mcc.fcvi.reset:notice]: Call home for METROCLUSTER FCVI RESET
[Node-A: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is up on port 0f.
porterrshow
命令的输出报告了ISL端口上的许多enc in, enc out, crc err, crc g_eof, bad e0f
和link fail
错误:
SwitchA:admin> porterrshow
porterrshow :
frames enc crc crc too too bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
tx rx in err g_eof shrt long eof out c3 fail sync sig tx rx err err
40: 317.6g 404.5g 2.8k 2.5k 2.5k 1 0 56 151.2k 120 51.4k 0 3 0 0 0 51 0 0
41: 462.1g 544.0g 0 0 0 0 0 0 3.3k 298 1 0 3 0 0 0 128 0 0