在更换控制器期间、出现错误"发现名称相同但系统ID不同的重复filer_table条目"
- Views:
- 97
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>1076865</a>
- Last Updated:
适用场景
- MetroCluster 双节点
- ONTAP 9
- 控制器更换
- 未执行MetroCluster 修复
问题描述
在维护模式下重新分配磁盘后、将显示以下错误
May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found
示例:
*> disk reassign -s 1234567 -d 7654321
Disk ownership will be updated on all disks previously belonging to Filer with sysid 7654321.
May 15 20:31:40 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321)
Do you want to continue (y/n)? y
May 15 20:31:42 [node1:diskown.duplicateSoftEntries:notice]: Found duplicate filer_table entries with same name node1 but different system ids (1234567,7654321) Unable to complete disk reassign successfully (Error: No disks specified).
May 15 20:31:42 [node1:diskown.ReassignFailed:error]: Disk reassign request failed. Reason: No disks found