在 MetroCluster 交换机升级期间,前端停止提供数据
适用场景
- AFF-A220
- MetroCluster IP
- 后端交换机升级
- ONTAP <9.7P15
- ONTAP <9.8P7
- ONTAP <9.9.1P1
问题描述
升级此 MetroCluster IP 配置前端中的后端交换机时,停止提供数据。
从事件日志中可以看到以下内容
[Node-01: intr: netif.linkDown:info]: Ethernet e0a: Link down, check cable. [Node-01: intr: netif.linkDown:info]: Ethernet e0a-10: Link down, check cable. [Node-01: intr: netif.linkUp:info]: Ethernet e0a: Link up. [Node-01: intr: netif.linkUp:info]: Ethernet e0a-10: Link up. [Node-01: wafl_exempt02: wafl.cp.toolong:error]: Aggregate aggr_root experienced a long CP. [Node-01: wafl_exempt00: wafl.cp.toolong:error]: Aggregate aggr_data experienced a long CP. [Node-01: diskown.errorDuringIO:error]: error 23 (adapter error prevents command from being sent to device) on disk 0m.i1.1L26 (S/N HLY12300) while reading individual disk ownership area