适用场景

  • ONTAP 9.9.x
  • MetroCluster

问题解答

  • 在MetroCluster环境中、LUN不会复制到其他站点、因为它是在聚合中进行的复制。
  • 例如、一个卷将在同一聚合中具有2个副本—一个在本地丛上、一个在远程丛上。数据读取主要发生在本地丛中、但写入同时发生在本地丛和远程丛中。磁盘在远程丛中的物理位置为其他站点。这就是当一个站点发生故障时我们仍然拥有数据的方式。
  • 调整完LUN大小后、请 重新同步Vserver 、以便在另一端镜像LUN大小。

追加信息

不适用
NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.