问题描述

在主节点配置复制服务(CRS)上禁用集群间LIF会导致SVM (SVM)运行不正常。

 

仅通过LIF已启动的节点运行集群对等运行状况:
mcc-siteA::*> cluster peer health show

Node         Cluster Name                Node-Name
----         ------------         ---------

             Ping-Status            RDB-Health    Cluster-Health   Availability
----------   ------------               ------------   --------------   -------------
mcc-siteA-01  mcc-siteB   mcc-siteB-01
              Data: interface_reachable
              ICMP: interface_reachable   true              true            true
                          mcc-siteB-02
             Data: interface_reachable
             ICMP: interface_reachable    true              true            true
mcc-siteA-02
             mcc-siteB   mcc-siteB-01
             Data: unreachable
              ICMP: unreachable           true          true            false
                          mcc-siteB-02
             Data: unreachable
             ICMP: unreachable          true          true            false

 

MetroCluster Vserver运行状况不正常:
mcc-siteA::*> metrocluster vserver show

Cluster: mcc-siteA-ams1
                            Partner                       Configuration
Vserver                     Vserver                       State
-------------------         ----------------------        -----------------
mcc-siteA-ams1              mcc-siteB                    unhealthy

Cluster: mcc-siteB
                            Partner                       Configuration
Vserver                     Vserver                       State
-------------------         ----------------------        -----------------
mcc-siteB                 mcc-siteA                      unhealthy
vs_cifs                     vs_cifs-mc                     unhealthy
3 entries were displayed.

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.