适用场景
- ONTAP 9
- 光纤 MetroCluster
问题描述
- MetroCluster系统中的灾难恢复镜像已关闭:
Cluster_A::> metrocluster interconnect show
Mirror Mirror
Partner Admin Oper
Node Partner Name Type Status Status Adapter Type Status
---- ------------ ------- -------- ------- ------- ------ ------
ClusterA-01
ClusterB-01
DR enabled online
fcvi_device_0
FC-VI Up
fcvi_device_1
FC-VI Down
2 entries were displayed.
- 节点上的FCVI端口已关闭:
slot 2: FCVI Host Adapter 2b (QLogic 8324(2672) rev. 2, unknown)
Physical link: DOWN
FC Node Name: 21:00:XX:XX:XX:XX:XX:XX
Firmware rev: 8.01.141
- 连接到FCVI端口的交换机端口没有指示灯:
switchshow :
switchName: MCC-SW4
switchType: 181.0
switchState: Online
Index Port Address Media Speed State Proto
==================================================
0 0 080000 id 16G No_Light FC
- 连接到交换机端口的SFP没有接收电源:
MCC-SW4:admin> sfp show 0
=============
Port 0:
=============
Current: 7.496 mAmps
Voltage: 3254.4 mVolts
RX Power: -inf dBm (0.0 uW)
TX Power: -1.4 dBm (732.5 uW)