DR配置复制失败:对对象generation_cert应用失败
- Views:
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2009634485</a>
- Last Updated:
适用场景
- ONTAP 9
- MetroCluster
- 已生成DR配置复制AutoSupport
问题描述
metrocluster vserver show
报告降级的Vserver:Vserver : svm1
Partner Vserver : svm1-mc
Configuration State : degraded
Stream Status : operation-failed
Corrective Action : Resynchronize the configuration using "metrocluster vserver resync" command. Contact technical support for assistance if configuration-state does not change to healthy.
Failed Row : Table Name: generate_cert, Operation: get, Fields: svm1-mc
Failed Reason : Apply failed for Object: generate_cert Method: baseline. Reason: duplicate entry