DR配置复制失败-原因:无法将字段"vServer"设置为"SVM1-MC"
适用场景
- MetroCluster
- ONTAP 9
问题描述
degraded
输出中包含一个或多个Vserver metrocluster vserver show
示例:
Cluster : ClusterA
Vserver : SVM1
Partner Vserver : SVM1-mc
Configuration State : degraded
Stream Status : idle
Failed Row : Table Name: vifsbyname, Operation: get, Fields: ---------------
Failed Reason : vifsbyname Method: baseline. Reason: failed to set field "vserver" to "SVM1-mc"
Last apply fail time : 3/29/2020 12:25:41