跳转到主内容

DR配置复制失败-错误:在节点上找不到联机FC端口

Views:
1
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009年649501</a>
Last Updated:

适用场景

  • MetroCluster
  • ONTAP 9
  • FC数据网络

问题描述

  • 从一个或多个节点触发名为DR配置复制失败的AutoSupport
  • metrocluster vserver show 显示一个或多个Vserver的错误

示例:

                Cluster  : ClusterA
                Vserver  : SVM1
            Partner Vserver  : SVM1-mc
          Configuration State  : syncing
             Stream Status  : processing-task
               Failed Row : Table Name: vifsbyname, Operation: get, Fields: SVM1-mc FCP-LIF ...
             Failed Reason : Unrecoverable error during configuration replication, requires manual                            intervention. Error: Cannot find online FC ports on Node "ClusterA-01" for                         placing LIF "FCP-LIF" in Vserver "SVM1-mc".
         Last apply fail time  : 3/29/2020 12:25:41

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.