MetroCluster IP远程驱动器上的磁盘擦除奇偶校验不一致
适用场景
- MetroCluster IP
- ONTAP 9
问题描述
Fri Aug 06 02:52:39 +0000 [ClusterB-N1: scsi_cmdblk_strthr_admin: scsi.cmd.checkCondition:error]: Disk device 0m.i2.1L121: Check Condition: CDB 0x28:966c9600:0200: Sense Data SCSI:recovered error - (0x1 - 0xb 0x97 0x97)(93).
Fri Aug 06 02:52:39 +0000 [ClusterB-N1: disk_server_1: disk.ioRecoveredError.retry:info]: Recovered error on disk 0m.i2.1L121: op 0x28:966c9600:0200 sector 10 SCSI:recovered error - Disk used internal retry algorithm to obtain data (1 b 97 97) (94) Disk 0m.i2.1L121 Shelf 14 Drawer 3 Slot 9 Bay 33 [NETAPP X377_HLBRE10TA07 NA01] S/N [] UID [5000CCA2:A23F774C:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
Fri Aug 06 02:52:39 +0000 [ClusterB-N1: disk_server_1: disk.IO.status:debug]: params: {'deviceName': '0m.i2.1L121', 'returnCode': '5', 'pathRetryCount': '0', 'adapterStatus': '0x0', 'cdb': '0x28:966c9600:0200', 'basicTimeout': '14', 'iASCQ': '0x97', 'iSenseKey': '0x1', 'sSenseCode': '', 'ETime': '94', 'iASC': '0xb', 'victimRetryCount': '0', 'sSenseKey': 'SCSI:recovered error', 'targetStatus': '0x2', 'disk_information': 'Disk 0m.i2.1L121 Shelf 14 Drawer 3 Slot 9 Bay 33 [NETAPP X377_HLBRE10TA07 NA01] S/N [] UID [00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'retryCount': '0', 'pathsTried': '0', 'timeoutRetryCount': '0'}
Fri Aug 06 02:52:39 +0000 [ClusterB-N1: raidio_thread: raid_scrub_lw_id_inconsist_1:notice]: params: {'owner': '', 'rg': '/NodeB1_data_aggr01/plex1/rg0', 'more_stripes': '-1', 'stripe': '315462336'}
Fri Aug 06 05:00:01 +0000 [ClusterB-N1: config_thread: raid.rg.scrub.summary.lw:notice]: Scrub found 64 RAID write signature inconsistencies in /Node1_data_aggr01/plex1/rg0.
Fri Aug 06 05:00:02 +0000 [ClusterB-N1: config_thread: callhome.dsk.scrub.parity:alert]: Call home for
DISK SCRUB PARITY INCONSISTENCY