一个 ATTO 网桥发现校验和错误
- Views:
- 13
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- MetroCluster
- Last Updated:
- Invalid Date
适用场景
- ONTAP 9
- 光纤 MetroCluster
问题描述
在 RAID 擦除期间会报告大量校验和错误,并且识别的磁盘均通过同一交换机端口进行访问
示例:
[ClusterA-n1: raidio_thread: raid_rg_scrub_cksum_err_1:notice]: params: {'disk_rpm': 'N/A', 'vendor': 'NETAPP ', 'firmware_revision': 'NA54', 'shelf': '30', 'disk_info': 'Disk /CA_aggr1_n1/plex1/rg0/FabA-SW1:9.126L36 Shelf 30 Bay 9 [NETAPP X357_S163A3T8ATE NA54] S/N [00000000000000] UID [5002538A:478418B0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Remote', 'bay': '9', 'carrier': '', 'serialno': 'S394NX0J801388', 'owner': '', 'model': 'X357_S163A3T8ATE', 'disk_type': '5', 'blockNum': '458328767'}
[ClusterA-n1: raidio_thread: raid_rg_readerr_repair_data_1:notice]: params: {'site': 'Remote', 'disk_rpm': 'N/A', 'vendor': 'NETAPP ', 'firmware_revision': 'NA54', 'shelf': '30', 'disk_info': 'Disk /CA_aggr1_n1/plex1/rg0/FabA-SW1:9.126L36 Shelf 30 Bay 9 [NETAPP X357_S163A3T8ATE NA54] S/N [00000000000000] UID [5002538A:478418B0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'vbn': '1395938814', 'bay': '9', 'carrier': '', 'serialno': 'S394NX0J801388', 'owner': '', 'model': 'X357_S163A3T8ATE', 'disk_type': '5', 'blockNum': '458328766'}
[ClusterA-n1: raidio_thread: raid_rg_readerr_repair_cksum_error_1:notice]: params: {'disk_rpm': 'N/A', 'vendor': 'NETAPP ', 'firmware_revision': 'NA54', 'shelf': '30', 'disk_info': 'Disk /CA_aggr1_n1/plex1/rg0/FabA-SW1:9.126L36 Shelf 30 Bay 9 [NETAPP X357_S163A3T8ATE NA54] S/N [00000000000000] UID [5002538A:478418B0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Remote', 'bay': '9', 'carrier': '', 'serialno': 'S394NX0J801388', 'owner': '', 'model': 'X357_S163A3T8ATE', 'disk_type': '5', 'blockNum': '458328766'}
[ClusterA-n1: raidio_thread: raid_rg_readerr_repair_cksum_stored_1:notice]: params: {'disk_rpm': 'N/A', 'vendor': 'NETAPP ', 'firmware_revision': 'NA54', 'shelf': '30', 'disk_info': 'Disk /CA_aggr1_n1/plex1/rg0/FabA-SW1:9.126L36 Shelf 30 Bay 9 [NETAPP X357_S163A3T8ATE NA54] S/N [00000000000000] UID [5002538A:478418B0:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Remote', 'bay': '9', 'carrier': '', 'serialno': 'S394NX0J801388', 'owner': '', 'model': 'X357_S163A3T8ATE', 'disk_type': '5', 'blockNum': '458328767'}
[ClusterA-n1: raidio_thread: raid_rg_readerr_repair_data_1:notice]: params: {'site': 'Remote', 'disk_rpm': 'N/A', 'vendor': 'NETAPP ', 'firmware_revision': 'NA54', 'shelf': '30', 'disk_info': 'Disk /CA_aggr1_n1/plex1/rg0/FabB-SW1:9.126L41 Shelf 30 Bay 14 [NETAPP X357_S163A3T8ATE NA54] S/N [00000000000000] UID [5002538A:47842530:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'vbn': '8023985918', 'bay': '14', 'carrier': '', 'serialno': '00000000000000', 'owner': '', 'model': 'X357_S163A3T8ATE', 'disk_type': '5', 'blockNum': '523068798'}
[ClusterA-n1: raidio_thread: raid_rg_readerr_repair_cksum_error_1:notice]: params: {'disk_rpm': 'N/A', 'vendor': 'NETAPP ', 'firmware_revision': 'NA54', 'shelf': '30', 'disk_info': 'Disk /CA_aggr1_n1/plex1/rg0/FabB-SW1:9.126L41 Shelf 30 Bay 14 [NETAPP X357_S163A3T8ATE NA54] S/N [00000000000000] UID [5002538A:47842530:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]', 'site': 'Remote', 'bay': '14', 'carrier': '', 'serialno': '00000000000000', 'owner': '', 'model': 'X357_S163A3T8ATE', 'disk_type': '5', 'blockNum': '523068798'}
如示例所示,通常会立即检测并修复这些错误。