跳转到主内容

ATto网桥FC端口脱机、ATto网桥上的RX低

Views:
10
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster<a>2009582826.</a>
Last Updated:

适用场景

  • MetroCluster FC
  • ONTAP 9
  • ATTO FibreBridge 7500N/7600N

问题描述

  • storage bridge show -name ATTO_XXXXXXXXXXXXXXXX 显示:

BridgeStatus: error

BridgeError Description List: ATTO_XXXXXXXXXXXXXXXX(XXXXXXXXXXXXXXXX):FC_PORT_1 is Offline.

  • 网桥 dmpconfig 输出显示FC端口已关闭、数据速率和连接模式显示为不适用:

; Port   Status

;===============

1    Down

2    Up

FC1 DataRate     = N/A

FC1Connection Mode  = N/A

  • dmpconfig 还会显示RX低:

getFCSFPPower all

FC SFPinformation for port 1:

Tx power: 700.0uW

Rx power: 120.0uW

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.