问题描述
adapterHardwareErrorEMSOnly
调解器磁盘的MetroCluster报告中的所有节点。
[site1node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.0 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.0 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:00000008:0008. Disk 0f.1 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.3 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.2 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c0:0008. Disk 0f.3 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.2 Shelf - Bay - [NETAPP PHA-DISK 0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000
- 如果禁用了自动计划外切换(Automatic Undar计划 外切换、AUSO)功能、并且调解器磁盘报告运行状况不正常、则会出现上述错误。
site1node1 ERROR mcc.config.auso.stDisabled: The state of Automatic Unplanned Switchover capability has been disabled.
site1node1 ERROR cf.mccip.med.auso.stDisabled: Automatic switchover disabled: Mediator mailbox disk not healthy.
- 这些问题会多次报告。