适用场景

  • ONTAP 9
  • MetroCluster IP
  • 调解器

问题描述

  • adapterHardwareErrorEMSOnly 调解器磁盘的MetroCluster报告中的所有节点。

[site1node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.1 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.0 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

[site1node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.0L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.0 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [34XXXXXXXXXXXX34] UID [34XXXXXX:XXXXXX34:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site1node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.1L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:00000008:0008. Disk 0f.1 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [35XXXXXXXXXXXX33] UID [35XXXXXX:XXXXXX33:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

[site2node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:0000a410:0008. Disk 0f.3 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node1: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c8:0008. Disk 0f.2 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]

[site2node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.3L0: Adapter detected hardware error: HA status 0x6: cdb 0x2a:0000a5c0:0008. Disk 0f.3 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [37XXXXXXXXXXXX64] UID [37XXXXXX:XXXXXX64:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000]
[site2node2: pha_main000: scsi.cmd.adapterHardwareErrorEMSOnly:error]: Disk device 0f.2L0: Adapter detected hardware error: HA status 0x6: cdb 0x28:00000008:0008. Disk 0f.2 Shelf - Bay - [NETAPP   PHA-DISK         0001] S/N [36XXXXXXXXXXXX61] UID [36XXXXXX:XXXXXX61:00000000:00000000:00000000:00000000:00000000:00000000:00000000:00000000

  • 如果禁用了自动计划外切换(Automatic Undar计划 外切换、AUSO)功能、并且调解器磁盘报告运行状况不正常、则会出现上述错误。

site1node1  ERROR  mcc.config.auso.stDisabled: The state of Automatic Unplanned Switchover capability has been disabled.
site1node1  ERROR  cf.mccip.med.auso.stDisabled: Automatic switchover disabled: Mediator mailbox disk not healthy.

  • 这些问题会多次报告。

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.