在节点重命名后、集群仍可看到配对节点的旧节点名称
适用场景
- ONTAP 9
- 节点重命名
问题描述
启用交换机日志记录会导致ping错误、并指向不同的节点名称
- 命令
metrocluster check show
可显示聚合、集群和卷的ping错误
All checks could not be run as there was an internal error.
The "ping" command terminated using the network addresses "10.1.1.3" and "10.1.1.4" on node "hcgnxc12-01" in cluster "hcgnxc12". Reason: invalid operation
metrocluster check run
导致警告
InterclusterBrokenConnectionAlert
Ping Error: The "ping" command terminated using the network addresses "10.1.1.1" and "10.1.1.3" on node "hcgnxc11-01" in cluster "hcgnxc11". Reason: invalid operation
Storage Error: Unable to monitor the iSCSI daemons on node "hcgnxc11-01" in cluster "hcgnxc11". Reason: (invalid operation)
MTU Size Error: The "ping" command terminated using the network addresses "10.1.1.1" and "10.1.1.2" on node "hcgnxc11-01" in
cluster "hcgnxc11". Reason: invalid operation