跳转到主内容

ATTO意外重新启动错误1 0x52004 C6F

Views:
3
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
metrocluster
Last Updated:

适用场景

  • MetroCluster FC
  • ONTAP 9
  • ATTO Fibrebridge 7500N/7600N

问题描述

FibreBridge意外重新启动、FibreBridge日志显示:
2F1C9F 17:23:41 02/03/23 CRIT FC Chip Error, Status: 0x81000000, Error1: 0x52004C6F, 2F1CA0 17:23:41 02/03/23 CRIT Error2: 0x10010401 on FC Port 2 2F1CA1 17:23:41 02/03/23 CRIT Software Interrupt Exception Detected (SWI) (001L) 2F1CA2 17:23:41 02/03/23 CRIT Instr Address = 001daca4 2F1CA3 17:23:41 02/03/23 CRIT SWI Number = 0x000000 2F1CA4 17:23:41 02/03/23 INFO Software Interrupt 2F1CA5 17:23:41 02/03/23 INFO 02/03/2023 17:23:41 2F1CA6 17:23:41 02/03/23 INFO ST[1ba13000-1ba14000] | FP[1ba13b8c] CPSR[60000193] 2F1CA7 17:23:41 02/03/23 INFO 0014c54c<-00266674 | SP[1ba13b90] FP[1ba13bfc] 2F1CA8 17:23:41 02/03/23 INFO 00266548<-00000584 | SP[1ba13c00] FP[1ba13c44] 2F1CA9 17:23:41 02/03/23 INFO 001da36c<-00d2844c | SP[1ba13c48] FP[1ba13f74] 2F1CAA 17:23:41 02/03/23 INFO 00d27f98<-00d0d3d0 | SP[1ba13f78] FP[1ba13fa4] 2F1CAB 17:23:41 02/03/23 INFO 00d0d33c<-00d13324 | SP[1ba13fa8] FP[1ba13fcc] 2F1CAC 17:23:41 02/03/23 INFO 00d130d0<-000417e4 | SP[1ba13fd0] FP[1ba13ffc] 2F1CAD 17:23:41 02/03/23 INFO 00041688<-003ec590 | SP[1ba14000] FP[1ba14000] 2F1CAE 17:23:41 02/03/23 INFO Exception occurred. Possible redundant preceding log entries 2F1CAF 00:00:05 01/01/00 INFO Reset. HW Code: Software Warm 2F1CB0 00:00:05 01/01/00 INFO Reset. Reason: Critical Software Error Detected 2F1CB1 17:26:26 02/03/23 SYS System date has changed. Current date:[02/03/2023] 2F1CB2 17:26:26 02/03/23 INFO Boot/reset occurred (001L) 2F1CB3 17:26:26 02/03/23 INFO Checkpoint 42 B:0 S0:0:0 S1:0:0 D0:0 C:0 O:0 I:0

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.