过热后无法访问 ATTO FibreBridge
适用于
ATTO 6500N
ATTO 7500N
ATTO 7600N
MetroCluster
温度过高
ATTO 7500N
ATTO 7600N
MetroCluster
温度过高
日志消息:
1D0AA8 00:36:43 WARN Temperature Critical Level reached at 71 C
1D0AA9 00:36:45 CRIT Temperature (71 C) out-of-range (0, 70 C). Going offline.
问题
ATTO 网桥报告为已删除,并报告类似以下内容的错误消息:
Sat Feb 4 16:06:38 CET [netapp01:bridge.removed:info]: FC-to-SAS bridge sw2:5.125L0 [ATTO FibreBridge6500N 1.11] S/N [FB6500N123456] was removed.