由于电源线问题、ATto 7500N/7600N光纤桥接电源出现故障
- Views:
- 5
- Visibility:
- Public
- Votes:
- 0
- Category:
- metrocluster
- Specialty:
- metrocluster<a>2010068973</a>
- Last Updated:
适用场景
- ATto 7500N光纤桥接
- ATto 7600N光纤桥接
问题描述
- 并非ATto 7500N/7600N光纤网桥的所有电源都已联机
- 目前不进行电力维护
- 电源没有问题描述-不同的插座/PDU仍有错误:
警告: 出于故障排除目的、请勿重新拔插电源。 |
- 事件日志报告电源出现故障:
Tue Jul 11 15:02:12 +0200 [NodeA_1: dsbridge_admin: fc.bridge.power.alert:alert]: Fibre Channel FibreBridge7600N Bridge ATTO_200000xxxxxx S/N: FB7600Nxxxxxx WWN: 200000xxxxxx Power Supply A has failed.
- ONTAP报告电源出现故障的错误:
::>system health alert show -alert-id StorageBridgePowerSupplyFailed_Alert
Node: node01 Resource: Power Supply Severity: Major Indication Time: Wed Nov 17 21:25:25 2021 Suppress: false Acknowledge: false Probable Cause: Power Supply B of "ATTO_10.x.x.x" has failed. Possible Effect: If the remaining power supply fails, "ATTO_10.x.x.x" will go offline, causing a loss of path redundancy to storage. Corrective Actions: 1) Check the power source for the bridge, the power cords and fuses. 2) If the problem cannot be corrected, replace the failed power supply.