跳转到主内容

(磁盘冗余失败)错误和在网络结构MCC中触发的SCSI.path.excesisveErrors

Views:
2
Visibility:
Public
Votes:
0
Category:
metrocluster
Specialty:
HW
Last Updated:

适用场景

  • MetroCluster FC
  • ATTO FibreBridge
  • ONTAP 9

问题描述

  • EMS日志指示以下内容:

[node-01: slifc_timeout_1: scsi.path.excessiveErrors:error]: Excessive errors encountered by adapter 4b on disk device switch-06:10.126.
[node-01: slifc_intrd: scsi.cmd.abortedByHost:error]: Disk device switch-06:10.126L27: Command aborted by host adapter: HA status 0x4: cdb 0x28:0000a410:0008.
[node-01: slifc_intrd: scsi.cmd.retrySuccess:debug]: Disk device switch-06:11.126L27: request successful after retry #1/#0: cdb 0x28:0000a410:0008 (10990).
[node-01: svc_queue_thread: callhome.dsk.redun.fault:error]: Call home for DISK REDUNDANCY FAILED

  • ATto网桥的FC端口2发生卷动。

[node-01: dsbridge_admin: fc.bridge.fc.port.alert:alert]: Fibre Channel FibreBridge7600N Bridge ATTO_200000XXXXXX4300 S/N: FBXXXXX335 WWN: 200000XXXXXX4300 FC Port FC_PORT2 offline.
[node-01: dsbridge_admin: fc.bridge.fc.port.notice:notice]: Fibre Channel FibreBridge7600N Bridge ATTO_200000XXXXXX4300 S/N: FBXXXXX335 WWN: 200000XXXXXX4300 FC Port FC_PORT2 connected.

  • 系统将从"四路径HA"配置过渡到"多路径HA"。

[node-01: dsa_disc: shelf.config.tompha:info]: System has transitioned to multi-path HA attached storage

  • 网桥节点-01上的FC端口2上的错误持续增加(序列号:FBXXXXX335 )

  ::*> storage bridge show -stats

FC Port 22XXXXXX300:
  State:              up
  Speed:              unknown
  Topology:           point-to-point
 Link Failure Count: 21444               >>>>>> Flapping and count incrementing
  Loss of Sync Count: 38390               >>>>>> Incrementing count
  CRC Error Count:    5                   >>>>>> CRC is also seen but not incrementing

  LIP Count:          0
  Frames In:          7417273
  Frames Out:         12196874703
  SFP Vendor:         AVAGO
  SFP Part Number:    AFBR-57G5MZ-ELX
  SFP Serial Number:  AM2047G1SEC
  SFP Capabilities:   8, 16,

  • FC端口2连接到交换机FC_XXXX Brocade (符号名称:switch-06)端口10
  • 在Brocade交换机上、  porterrshow 显示在交换机的端口10中出现CRC和CRC_Geof错误以及pcs错误和uncorr错误

porterrshow:
       frames      enc crc crc   too  too  bad enc disc link loss loss frjt fbsy c3timeout pcs uncor
    tx     rx     in err g_eof shrt long eof out c3   fail sync sig          tx     rx err err

10: 69.8g 195.6g   0   34 25    0     0   9   0   2.1k 6.2k 0    7.4k  0    0  2.1k    0 2.1k  177.0k

  • 端口10的"sfpshow "表示Rx功率低

  =============
  Port 10:
  =============
  Identifier:  3    SFP
  Connector:   7    LC
  Transceiver: 6804406000000000 8,16,32_Gbps M5 sw Inter,Short_dist
  .
  Current:     7.496   mAmps
  Voltage:     3280.2  mVolts
 RX Power:    -8.3    dBm (149.6uW)    >>>>>>> Outside the range
  TX Power:    -1.2    dBm (758.5 uW)

  State transitions: 1
  Last poll time: 10-28-2024 CET Mon 09:22:43
  Extended smart data is Not available

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.