跳转到主内容

FVI端口上报告"Inter連AdapterOfflineAlert"

Views:
Visibility:
Public
Votes:
0
Category:
ontap-9
Specialty:
metrocluster
Last Updated:

适用场景

  • ONTAP 9
  • 延伸型 MetroCluster

问题描述

'InterconnectAdapterOfflineAlert' 在无交换机的双节点桥接延伸型MetroCluster中的FVI端口0f上报告。

::> system health alert show
        Node: node-01
      Alert ID: InterconnectAdapterOfflineAlert
      Resource: fcvi_device_0
      Severity: Major
   Indication Time: Tue Mar 18 09:18:56 2025
      Suppress: false
     Acknowledge: false
   Probable Cause: Physical link on port 0f is offline.
   Possible Effect: DR protection of NVRAM mirror might be compromised.
 Corrective Actions: 1. Ensure that the FC-VI link has not been tampered with.

EMS事件:

Tue Aug 20 12:55:29 +0000 [node-01: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 0f.
Tue Aug 20 12:55:29 +0000 [node-01: ispfcvi2500_port2: fcvi.link.down:notice]: params: {'alertId': 'InterconnectAdapterOfflineAlert', 'alertingResource': '500a098103b11710', 'alertingResourceName': '0f', 'possibleEffect': 'DR protection of NVRAM mirror might be compromised.', 'probableCause': 'Cable_tamper', 'probableCauseDescription': 'Physical link on port 0f is offline.', 'additionalInfo': 'None'}

Tue Aug 20 12:55:30 +0000 [node-02: ispfcvi2500_port2: fcvi.update.link.state:notice]: FC-VI adapter: Physical link is down on port 0f.
Tue Aug 20 12:55:30 +0000 [node-02: ispfcvi2500_port2: fcvi.link.down:notice]: params: {'alertId': 'InterconnectAdapterOfflineAlert', 'alertingResource': '500a098103b11790', 'alertingResourceName': '0f', 'possibleEffect': 'DR protection of NVRAM mirror might be compromised.', 'probableCause': 'Cable_tamper', 'probableCauseDescription': 'Physical link on port 0f is offline.', 'additionalInfo': 'None'}

 

 

Sign in to view the entire content of this KB article.

New to NetApp?

Learn more about our award-winning Support

NetApp provides no representations or warranties regarding the accuracy or reliability or serviceability of any information or recommendations provided in this publication or with respect to any results that may be obtained by the use of the information or observance of any recommendations provided herein. The information in this document is distributed AS IS and the use of this information or the implementation of any recommendations or techniques herein is a customer's responsibility and depends on the customer's ability to evaluate and integrate them into the customer's operational environment. This document and the information contained herein may be used solely in connection with the NetApp products discussed in this document.

 